Spring Apartments
Stories
2B + G + 11
Built-up Area
216,000
Services
Structural Design
RCC Framing (RCC Columns, flat slabs with drop panels) support the gravity loads while Shear Walls resist Lateral Loads. A Raft Foundation was adopted. RCC Outriggers were employed at 4th Floor and Roof.