Mall of Arabia

Stories 4B + G + 15
Built-up Area 790,000
Height 275
Services Structural Design
An essentially complete RCC frame (RCC Columns, flat slabs with drop panels) provides support for gravity loads. Resistance to lateral loads provided by Reinforced Concrete Columns (IMRF) and Shear walls. A Raft Foundation was adopted for this multi-story commercial and office building.